oxipres1
oxipres1
oxipres3stk

Oxipres 2 pos. complete

ITEM NUMBER ML3047312
Description

ML Oxipres™ - Oxidation Stability Tester

Accelerated shelf-life tests by analyzing the oxidation stability in pure fats and oils or foods and feeds containing fats and oils - without prior sample preparation.

Key features:

  • No sample preparation or extraction necessary
  • Well proven technology >30 years experience
  • Accelerated results - fast documentation
  • Used by leading companies worldwide
  • Very simple and user friendly
  • Extremely robust equipment
  • Low maintenance costs

The OXIPRES™ subjects the whole sample, without prior preparation, to a high oxidative-stress environment (high temperature and oxygen over-pressure) in order to evaluate, in a short period of time, the resistance to oxidation.
The oxygen uptake of the reactive components present in food-feed samples is monitored by the OXIPRES™ to evaluate the oxidative stability under accelerated oxidation conditions. Experiments indicate that results from the vessel method can be correlated to organoleptic tests.
Up to 9 OXIPRES™ instruments can be handled by the Paralog software which means that up to 18 pressure vessels can be run simultaneously. With multiple instruments you will also be able to run samples at individual temperatures. The OXIPRES™ also has an optional volatile-trap function for further GC-MS analysis.

Useable for the following matrices:

  • Encapsulated products
  • Roasted peanuts
  • Lubricating oil
  • Potato chips
  • Mayonnaise
  • Milk powder
  • Margarine
  • Fish flour
  • Cosmetic
  • Clean oil
  • Cookies
  • Pet food

Meets all demands in the methods ASTM D525 for testing the stability of fats and oils.

ML Oxipres™ comes with control unit, heater, 2 pressure vessels and accessories:

1 Rack for reaction 6 reaction vessels
4 Reaction vessels
2 O-rings
1 Cleaning kit for pressure vessel
1 Lifter for lid
1 Carbon filter
1 Adaptor for carbon filter

For a complete set-up we recommend:

Paralog software and USB-converter

Filling station - for easier filling and flushing of the pressure vessels. The filling station has a safety valve, and is available with 2 or 6 filling tubes

Holding rack for easier tightening of the pressure vessels

Calibration kit, for calibration of pressure and temperature

SPECIFICATIONS:

Voltage: 230/115 V AC (switchable)

Power consumption: (1 block heater) 4 A (8 A)

Space: Approx. 600 mm table length (excl. PC)

Sample volume: max. 125 ml. (The sample should normally contain 3-5 g fat).

Working pressure: Max. 10 bar (1 MPa)

Recommended pressure: 5 bar

Working temperature: ambient-180 ºC

Recommended temperature: 90 ºC

Signal output: 0-2,5 (5) V FS

Footprint (2/4/6 pos. -stacked): 39x68x40cm/78x68x40cm/117x68x40cm

Specifications
ITEM NUMBER ML3047312
Quantity / pk 1
Unit pcs
Minimum order 1
TariffNumber 90278990
Type Udstyr
Vægt 16,8
Tryk max (bar) Max. 10 bar (1 MPa)