zero_air_rack

GC, 10,0l/min Zero Air Gen. for 19" Rack Cabinet

Varenr. VDDBRGC10000

VICI GC-Rack, 10,0l/min Zero Air Gen. for 19" Rack Cabinet 230-240V/50-60Hz

Beskrivelse

GC Zero Air 19" rack cabinet - For GC-FID, TOC,CEM and Process Control Applications. The VICI DBS GC Zero Air Generator 19" Rack is designed to supply ultrapure hydrocarbon-free zero air for GC-FID applications. Catalytic oxidation technology eliminates hydrocarbons to <0.1ppm, resulting in a flat, stable baseline, increased sensitivity, and repeatable analysis.

GC Zero Air features:

  • Flow rate from 1.8 to 15 l/min
  • Pressure up to 6.5 bar (95 psig)
  • Zero air purity <0.1ppm HC,
  • Minimal maintenance
  • 2 year standard warranty

OPERATING PRINCIPLE
The 19" Zero Air Generator uses three steps to transform ambient air into analytical grade air.

STEP 1: PRE-FILTRATION
An external oil-free compressor delivers air through a high efficiency filter that traps any particles that may damage the system. The filter, which has an automatic purge system, traps oil, water, and any particles larger than 5 microns in size.

STEP 2: HC AND CO TRAPPING
The air leaving the filter enters a high temperature platinum catalyzer, which eliminates hydrocarbon molecules down to < 0.1 ppm through oxidation .

STEP 3: FINAL FILTRATION
A final pass through a high-efficiency filter prevents any kind of particles from entering the instrument.

BENEFITS

BETTER DETECTOR PERFORMANCE
The reduction of carbon monoxide and hydrocarbons (including methane) to < 0.1 ppm decreases the background noise level and gives the baseline much better stability, increasing detector sensitivity considerably and ensuring precise analytical results.

EASY INSTALLATION
Just connect a suitable oil-free compressor (optional). To save bench space, the unit can be easily wall-mounted.

LAB SAFETY
No more bottles in the lab and expensive pipelines for air distribution.

SAVE MONEY
All that the unit requires is a connection to a suitable oil-free compressor and the mains. Typically the investment is recovered in less than a year.

IMPROVED LAB EFFICIENCY
Round the clock continuous operation maximizes lab productivity, eliminating dead time for gas bottle changeover and avoiding the need for tedious instrument recalibrations.

Specifikationer
Varenr. VDDBRGC10000
Antal / pk 1
Enhed stk
Min. bestilling 1
Leverandørens varenummer DB-RGC10000-EU
UNSPSC 41103515
Type Udstyr
Type 2 Luft
Model GC-rack
Flow 10 l/min
Tilslutning Outlet: 1/8". Inlet: 1/4"
Temperatur (C) Max. temp in: 40°C
Spec. renhed <0.1 ppm (HC & CO out)
Trykområde Inlet: 4.5-10 bar
Power 220-240 V